Laminar Air Flow
Product Brochure
Brand | SSU |
Type | Horizontal |
Usage/Application | Laboratory |
Material | Wooden, MS and SS |
Surface Finish | Color Coated |
Voltage | 220-230 V |
Frequency | 50 Hz |
Height | 5.5 Feet |
Motor Power | 1/5 HP |
The cabinets are fabricated out of thick wooden/MS and SS Interior The worktable is made of thick clad at top SS sheet. Side panels are made out of thick transparent flexi glass duly Framed. The unit is fitted with pre-filter. Air is drawn through pre-filter and is made to pass through highly effective HEPA (High Efficiency Particular Air) filters having efficiency rating as high as 99.99% with Cold DOP and 99.97% with hot DOP. Thus retaining all air-biome particles of size 0.3 micron and larger. Using a dynamic machine, the blower and motor assembly is statically and dynamically balanced ESE MARKED Motor of 1/5 H.P. capacity operates with minimum noise level. The working area is illuminated By fluorescent lighting fitted to the unit. Height of the working table provides comfortable “SIT DOWN” Working position for the operation. To work on 220/230 volts A.C. supply. Supplied complete with sun mica Table top, HEPA filters, pre-filter and fluorescent illumination.
Laminar Flow Cabinet
Product Brochure
Brand | SSU |
Material | MS and Glass |
Surface Finish | Color Coated |
Usage/Application | Laboratory |
Voltage | 240 V |
Noise Level | 65 dBA |
Frequency | 50 Hz |
Treated air volume | 300-800 M3/h |
Model Number | SSU-140A |
LAMINAR AIR FLOW (HORIZONTAL)
Make: SSU.
Specification:
The body is constructed in double walled M.S.
The work table is made of stainless steel 304 grade.
All joints are sealed with scholastic sealant.
Transparent front and side panels of UV resistant Polycarbonate sheet fully transparent fixed with clamps.
The unit is fitted with per-filter and is made to pass through highly effective HEPA (High Efficiency Particular Air) filter having efficiency rating as high as 99.97% with cold, DOP, thus retaining all air-borne particles of size : 0.3 micron and larger.
Using a dynamic machine, the blower and motor assembly ISI marked is statically and dynamically balanced.
Blower Assembly with high RPM motor, enclosed in an SS casing suitably suspended in a pair springs & connected to the filter chamber through flexible canvas duct
Blowers are mounted on vibration isolation mounts to Minimize vibration and possess noiseless operation.
Height of the working table provides comfortable “ Sit Down” working position for the operation to work on 220/230 volts AC. Supply
Individual controlling switch & indicator for blower, UV And fluorescent tubes.
Technical Detail
Working Size : 3ft x 2ft x2ft (WxDxH)
Table : SS 304grade Platform
Pre Filter : Media Synthetic, non-woven polyester fibers (2nos)3ft x 2ft x6"of 10 micron
HEPA Filters : Media Ultra clean glass fiber paper -
imported down to 0.3 micron
HEPA size : 3ft x 2ft x 6” (2nos)
Retention : 0.3 Micron
Efficiency : 99.97%
Air Flow : Horizontal
Door : UV resistant polycarbonate door in
front facia with magnet lock
Add on feature: Provision of cock ( air , vacuum) 1
UV tube : 1x15W Philips
Fluorescent tube: 1x15W Philips
Blower Assembly :DIDW type ISI marked assembly
motors)
Leg Levellers : To adjust by +/- 10 mm
Noise level : >= 65 DB
Manometer : 0-100 mm
Power :220-230 Volts, 50 Hz Single Phase
Micro proser based controller with UV light and florescent light and blower sapped controller.Tissue Culture Rack
Product Brochure
Usage/Application | Laboratory |
Product Type | Storage Rack |
Height | 5.5 Feet |
Surface Treatment | Powder Coated |
Material | Iron |
Load Per Layer | 50-100 kg |
Number Of Shelves | 5 Shelves |
Made out of tubular m.s pipes/ tubular aluminum pipe duly painted for longer life. Each rack of size 48”x21” depth is covered with thick unbreakable Plexiglas distance between each rack is 15” each rack is fitted with 4 fluorescent tube,4 bulbs and one u.v germicidal light. Copper choke are fitted on a separate wooden plank fitted with caster wheels at its base, so that the chokes cube be placed outside the tissue culture room, if desired so as to avoid heat dissipation inside the air conditioned room.
Horizontal Laminar Air Flow
Minimum Order Quantity: 1 Piece
Product Brochure
Brand | SSU |
Type | Horizontal |
Material | SS and MS |
Surface Finish | Color Coated |
Usage/Application | Laboratory |
Voltage | 220-240 V |
Noise Level | 65 dBA |
Model Name/Number | SSU 140 B |
Power Source | Electric |
LAMINAR AIR FLOW (HORIZONTAL)
Make: SSU.
Specification:
The body is constructed in double walled S.S.
The work table is made of stainless steel 304 grade.
All joints are sealed with scholastic sealant.
Transparent front and side panels of UV resistant Polycarbonate sheet fully transparent fixed with clamps.
The unit is fitted with per-filter and is made to pass through highly effective HEPA (High Efficiency Particular Air) filter having efficiency rating as high as 99.97% with cold, DOP, thus retaining all air-borne particles of size : 0.3 micron and larger.
Using a dynamic machine, the blower and motor assembly ISI marked is statically and dynamically balanced.
Blower Assembly with high RPM motor, enclosed in an SS casing suitably suspended in a pair springs & connected to the filter chamber through flexible canvas duct
Blowers are mounted on vibration isolation mounts to Minimize vibration and possess noiseless operation.
Height of the working table provides comfortable “ Sit Down” working position for the operation to work on 220/230 volts AC. Supply
Individual controlling switch & indicator for blower, UV And fluorescent tubes.
Technical Detail
Working Size : 4ft x 2ft x2ft (WxDxH)
Table : SS 304grade Platform
Pre Filter : Media Synthetic, non-woven polyester fibers (2nos)4ft x 2ft x6"of 10 micron
HEPA Filters : Media Ultra clean glass fiber paper -
imported down to 0.3 micron
HEPA size : 3ft x 2ft x 6” (2nos)
Retention : 0.3 Micron
Efficiency : 99.97%
Air Flow : Horizontal
Door : UV resistant polycarbonate door in
front facia with magnet lock
Add on feature: Provision of cock ( air , vacuum) 1
UV tube : 1x15W Philips
Fluorescent tube: 1x15W Philips
Blower Assembly :DIDW type ISI marked assembly
motors)
Leg Levellers : To adjust by +/- 10 mm
Noise level : >= 65 DB
Manometer : 0-100 mm
Power :220-230 Volts, 50 Hz Single Phase
Micro proser based controller with UV light and florescent light and blower sapped controller.Additional Information:
- Production Capacity: any capacity
- Delivery Time: 7 days
- Packaging Details: cartoon packing
Vertical Laminar Flow Cabinet
Product Brochure
Brand | SSU |
Usage/Application | Laboratory |
Type | Vertical |
Material | MS |
Surface Finish | Powder Coated |
Model Name/Number | SSU-140 |
Size | 3 Feet x 2 Feet x 6 Inch |
Voltage | 220-240 V |
Power Supply | Electric |
Noise Level | 65 dBA |
Efficiency | 99.97% |
Retention | 0.3 Micron |
LAMINAR AIR FLOW (HORIZONTAL)
Make: SSU.
Specification:
The body is constructed in double walled M.S.
The work table is made of stainless steel 304 grade.
All joints are sealed with scholastic sealant.
Transparent front and side panels of UV resistant Polycarbonate sheet fully transparent fixed with clamps.
The unit is fitted with per-filter and is made to pass through highly effective HEPA (High Efficiency Particular Air) filter having efficiency rating as high as 99.97% with cold, DOP, thus retaining all air-borne particles of size : 0.3 micron and larger.
Using a dynamic machine, the blower and motor assembly ISI marked is statically and dynamically balanced.
Blower Assembly with high RPM motor, enclosed in an SS casing suitably suspended in a pair springs & connected to the filter chamber through flexible canvas duct
Blowers are mounted on vibration isolation mounts to Minimize vibration and possess noiseless operation.
Height of the working table provides comfortable “ Sit Down” working position for the operation to work on 220/230 volts AC. Supply
Individual controlling switch & indicator for blower, UV And fluorescent tubes.
Technical Detail
Working Size : 3ft x 2ft x2ft (WxDxH)
Table : SS 304grade Platform
Pre Filter : Media Synthetic, non-woven polyester fibers (2nos)3ft x 2ft x6"of 10 micron
HEPA Filters : Media Ultra clean glass fiber paper -
imported down to 0.3 micron
HEPA size : 3ft x 2ft x 6” (2nos)
Retention : 0.3 Micron
Efficiency : 99.97%
Air Flow : Horizontal
Door : UV resistant polycarbonate door in
front facia with magnet lock
Add on feature: Provision of cock ( air , vacuum) 1
UV tube : 1x15W Philips
Fluorescent tube: 1x15W Philips
Blower Assembly :DIDW type ISI marked assembly
motors)
Leg Levellers : To adjust by +/- 10 mm
Noise level : >= 65 DB
Manometer : 0-100 mm
Power :220-230 Volts, 50 Hz Single Phase
Micro proser based controller with UV light and florescent light and blower sapped controller.